M141 Heated Chamber, Temperature rework (#12201)
This commit is contained in:
@ -112,6 +112,20 @@
|
||||
#define WATCH_BED_TEMP_INCREASE 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Thermal Protection parameters for the heated chamber.
|
||||
*/
|
||||
#if ENABLED(THERMAL_PROTECTION_CHAMBER)
|
||||
#define THERMAL_PROTECTION_CHAMBER_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_CHAMBER_HYSTERESIS 2 // Degrees Celsius
|
||||
|
||||
/**
|
||||
* Heated chamber watch settings (M141/M191).
|
||||
*/
|
||||
#define WATCH_CHAMBER_TEMP_PERIOD 60 // Seconds
|
||||
#define WATCH_CHAMBER_TEMP_INCREASE 2 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
|
Reference in New Issue
Block a user