Merge branch 'Development' into fixup_leveling
Latest upstream commits
This commit is contained in:
@ -217,7 +217,6 @@ Here are some standard links for getting your machine calibrated:
|
||||
// is more then PID_FUNCTIONAL_RANGE then the PID will be shut off and the heater will be set to min/max.
|
||||
#define PID_INTEGRAL_DRIVE_MAX PID_MAX //limit for the integral term
|
||||
#define K1 0.95 //smoothing factor within the PID
|
||||
#define PID_dT ((OVERSAMPLENR * 10.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
|
||||
|
||||
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
|
||||
// Ultimaker
|
||||
@ -242,7 +241,7 @@ Here are some standard links for getting your machine calibrated:
|
||||
// Select PID or bang-bang with PIDTEMPBED. If bang-bang, BED_LIMIT_SWITCHING will enable hysteresis
|
||||
//
|
||||
// Uncomment this to enable PID on the bed. It uses the same frequency PWM as the extruder.
|
||||
// If your PID_dT above is the default, and correct for your hardware/configuration, that means 7.689Hz,
|
||||
// If your PID_dT is the default, and correct for your hardware/configuration, that means 7.689Hz,
|
||||
// which is fine for driving a square wave into a resistive load and does not significantly impact you FET heating.
|
||||
// This also works fine on a Fotek SSR-10DA Solid State Relay into a 250W heater.
|
||||
// If your configuration is significantly different than this and you don't understand the issues involved, you probably
|
||||
|
@ -218,7 +218,6 @@ Here are some standard links for getting your machine calibrated:
|
||||
// is more then PID_FUNCTIONAL_RANGE then the PID will be shut off and the heater will be set to min/max.
|
||||
#define PID_INTEGRAL_DRIVE_MAX PID_MAX //limit for the integral term
|
||||
#define K1 0.95 //smoothing factor within the PID
|
||||
#define PID_dT ((OVERSAMPLENR * 10.0)/(F_CPU / 64.0 / 256.0)) //sampling period of the temperature routine
|
||||
|
||||
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
|
||||
// Ultimaker
|
||||
@ -243,7 +242,7 @@ Here are some standard links for getting your machine calibrated:
|
||||
// Select PID or bang-bang with PIDTEMPBED. If bang-bang, BED_LIMIT_SWITCHING will enable hysteresis
|
||||
//
|
||||
// Uncomment this to enable PID on the bed. It uses the same frequency PWM as the extruder.
|
||||
// If your PID_dT above is the default, and correct for your hardware/configuration, that means 7.689Hz,
|
||||
// If your PID_dT is the default, and correct for your hardware/configuration, that means 7.689Hz,
|
||||
// which is fine for driving a square wave into a resistive load and does not significantly impact you FET heating.
|
||||
// This also works fine on a Fotek SSR-10DA Solid State Relay into a 250W heater.
|
||||
// If your configuration is significantly different than this and you don't understand the issues involved, you probably
|
||||
|
Reference in New Issue