Minimum temp options for Probing and G12 Nozzle Clean (#20383)
Co-authored-by: Jason Smith <jason.inet@gmail.com> Co-authored-by: Scott Lahteine <github@thinkyhead.com>
This commit is contained in:
committed by
Scott Lahteine
parent
87fbb89330
commit
588fec6474
@@ -1067,6 +1067,13 @@
|
||||
//#define PROBING_STEPPERS_OFF // Turn steppers off (unless needed to hold position) when probing
|
||||
//#define DELAY_BEFORE_PROBING 200 // (ms) To prevent vibrations from triggering piezo sensors
|
||||
|
||||
// Require minimum nozzle and/or bed temperature for probing.
|
||||
//#define PREHEAT_BEFORE_PROBING
|
||||
#if ENABLED(PREHEAT_BEFORE_PROBING)
|
||||
#define PROBING_NOZZLE_TEMP 120 // (°C) Only applies to E0 at this time
|
||||
#define PROBING_BED_TEMP 50
|
||||
#endif
|
||||
|
||||
// For Inverting Stepper Enable Pins (Active Low) use 0, Non Inverting (Active High) use 1
|
||||
// :{ 0:'Low', 1:'High' }
|
||||
#define X_ENABLE_ON 0
|
||||
@@ -1296,7 +1303,7 @@
|
||||
*/
|
||||
//#define PREHEAT_BEFORE_LEVELING
|
||||
#if ENABLED(PREHEAT_BEFORE_LEVELING)
|
||||
#define LEVELING_NOZZLE_TEMP 120
|
||||
#define LEVELING_NOZZLE_TEMP 120 // (°C) Only applies to E0 at this time
|
||||
#define LEVELING_BED_TEMP 50
|
||||
#endif
|
||||
|
||||
@@ -1666,6 +1673,10 @@
|
||||
// For a purge/clean station mounted on the X axis
|
||||
//#define NOZZLE_CLEAN_NO_Y
|
||||
|
||||
// Require a minimum hotend temperature for cleaning
|
||||
#define NOZZLE_CLEAN_MIN_TEMP 170
|
||||
//#define NOZZLE_CLEAN_HEATUP // Heat up the nozzle instead of skipping wipe
|
||||
|
||||
// Explicit wipe G-code script applies to a G12 with no arguments.
|
||||
//#define WIPE_SEQUENCE_COMMANDS "G1 X-17 Y25 Z10 F4000\nG1 Z1\nM114\nG1 X-17 Y25\nG1 X-17 Y95\nG1 X-17 Y25\nG1 X-17 Y95\nG1 X-17 Y25\nG1 X-17 Y95\nG1 X-17 Y25\nG1 X-17 Y95\nG1 X-17 Y25\nG1 X-17 Y95\nG1 X-17 Y25\nG1 X-17 Y95\nG1 Z15\nM400\nG0 X-10.0 Y-9.0"
|
||||
|
||||
|