Fix custom m-code behavior
Don’t set CUSTOM_M_CODE_SET_Z_PROBE_OFFSET if there’s no Z probe
This commit is contained in:
@ -537,9 +537,11 @@ const bool Z_MAX_ENDSTOP_INVERTING = true; // set to true to invert the logic of
|
||||
// Custom M code points
|
||||
#define CUSTOM_M_CODES
|
||||
#ifdef CUSTOM_M_CODES
|
||||
#define CUSTOM_M_CODE_SET_Z_PROBE_OFFSET 851
|
||||
#define Z_PROBE_OFFSET_RANGE_MIN -15
|
||||
#define Z_PROBE_OFFSET_RANGE_MAX -5
|
||||
#ifdef ENABLE_AUTO_BED_LEVELING
|
||||
#define CUSTOM_M_CODE_SET_Z_PROBE_OFFSET 851
|
||||
#define Z_PROBE_OFFSET_RANGE_MIN -15
|
||||
#define Z_PROBE_OFFSET_RANGE_MAX -5
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|
||||
|
Reference in New Issue