Add UNKNOWN_Z_NO_RAISE option

With this option enabled, Z won't ever be raised until after `G28` has been completed, and it won't raise if Z becomes unknown. This is good for machines whose beds fall when Z is powered off.
This commit is contained in:
Scott Lahteine
2018-03-09 23:18:47 -06:00
parent 3b4c89e4b5
commit 419d12ca1b
3 changed files with 25 additions and 9 deletions

View File

@ -804,6 +804,8 @@
//#define NO_MOTION_BEFORE_HOMING // Inhibit movement until all axes have been homed
//#define UNKNOWN_Z_NO_RAISE // Don't raise Z (lower the bed) if Z is "unknown." For beds that fall when Z is powered off.
//#define Z_HOMING_HEIGHT 4 // (in mm) Minimal z height before homing (G28) for Z clearance above the bed, clamps, ...
// Be sure you have this distance over your Z_MAX_POS in case.