Move Filament Width Sensor to Configuration_adv.h
This commit is contained in:
@ -1720,38 +1720,4 @@
|
||||
// With this option servos are powered only during movement, then turned off to prevent jitter.
|
||||
//#define DEACTIVATE_SERVOS_AFTER_MOVE
|
||||
|
||||
/**
|
||||
* Filament Width Sensor
|
||||
*
|
||||
* Measures the filament width in real-time and adjusts
|
||||
* flow rate to compensate for any irregularities.
|
||||
*
|
||||
* Also allows the measured filament diameter to set the
|
||||
* extrusion rate, so the slicer only has to specify the
|
||||
* volume.
|
||||
*
|
||||
* Only a single extruder is supported at this time.
|
||||
*
|
||||
* 34 RAMPS_14 : Analog input 5 on the AUX2 connector
|
||||
* 81 PRINTRBOARD : Analog input 2 on the Exp1 connector (version B,C,D,E)
|
||||
* 301 RAMBO : Analog input 3
|
||||
*
|
||||
* Note: May require analog pins to be defined for other boards.
|
||||
*/
|
||||
//#define FILAMENT_WIDTH_SENSOR
|
||||
|
||||
#if ENABLED(FILAMENT_WIDTH_SENSOR)
|
||||
#define FILAMENT_SENSOR_EXTRUDER_NUM 0 // Index of the extruder that has the filament sensor. :[0,1,2,3,4]
|
||||
#define MEASUREMENT_DELAY_CM 14 // (cm) The distance from the filament sensor to the melting chamber
|
||||
|
||||
#define MEASURED_UPPER_LIMIT 3.30 // (mm) Upper limit used to validate sensor reading
|
||||
#define MEASURED_LOWER_LIMIT 1.90 // (mm) Lower limit used to validate sensor reading
|
||||
#define MAX_MEASUREMENT_DELAY 20 // (bytes) Buffer size for stored measurements (1 byte per cm). Must be larger than MEASUREMENT_DELAY_CM.
|
||||
|
||||
#define DEFAULT_MEASURED_FILAMENT_DIA DEFAULT_NOMINAL_FILAMENT_DIA // Set measured to nominal initially
|
||||
|
||||
// Display filament width on the LCD status line. Status messages will expire after 5 seconds.
|
||||
//#define FILAMENT_LCD_DISPLAY
|
||||
#endif
|
||||
|
||||
#endif // CONFIGURATION_H
|
||||
|
@ -1255,6 +1255,40 @@
|
||||
//#define SPEED_POWER_MAX 100 // 0-100%
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Filament Width Sensor
|
||||
*
|
||||
* Measures the filament width in real-time and adjusts
|
||||
* flow rate to compensate for any irregularities.
|
||||
*
|
||||
* Also allows the measured filament diameter to set the
|
||||
* extrusion rate, so the slicer only has to specify the
|
||||
* volume.
|
||||
*
|
||||
* Only a single extruder is supported at this time.
|
||||
*
|
||||
* 34 RAMPS_14 : Analog input 5 on the AUX2 connector
|
||||
* 81 PRINTRBOARD : Analog input 2 on the Exp1 connector (version B,C,D,E)
|
||||
* 301 RAMBO : Analog input 3
|
||||
*
|
||||
* Note: May require analog pins to be defined for other boards.
|
||||
*/
|
||||
//#define FILAMENT_WIDTH_SENSOR
|
||||
|
||||
#if ENABLED(FILAMENT_WIDTH_SENSOR)
|
||||
#define FILAMENT_SENSOR_EXTRUDER_NUM 0 // Index of the extruder that has the filament sensor. :[0,1,2,3,4]
|
||||
#define MEASUREMENT_DELAY_CM 14 // (cm) The distance from the filament sensor to the melting chamber
|
||||
|
||||
#define MEASURED_UPPER_LIMIT 3.30 // (mm) Upper limit used to validate sensor reading
|
||||
#define MEASURED_LOWER_LIMIT 1.90 // (mm) Lower limit used to validate sensor reading
|
||||
#define MAX_MEASUREMENT_DELAY 20 // (bytes) Buffer size for stored measurements (1 byte per cm). Must be larger than MEASUREMENT_DELAY_CM.
|
||||
|
||||
#define DEFAULT_MEASURED_FILAMENT_DIA DEFAULT_NOMINAL_FILAMENT_DIA // Set measured to nominal initially
|
||||
|
||||
// Display filament width on the LCD status line. Status messages will expire after 5 seconds.
|
||||
//#define FILAMENT_LCD_DISPLAY
|
||||
#endif
|
||||
|
||||
/**
|
||||
* CNC Coordinate Systems
|
||||
*
|
||||
|
Reference in New Issue
Block a user