Heading for movement settings
This commit is contained in:
@ -420,9 +420,34 @@
|
||||
#define Z_MAX_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
|
||||
#define Z_MIN_PROBE_ENDSTOP_INVERTING true // set to true to invert the logic of the endstop.
|
||||
|
||||
|
||||
//=============================================================================
|
||||
//============================== Movement Settings ============================
|
||||
//=============================================================================
|
||||
// @section motion
|
||||
|
||||
//#define DEFAULT_AXIS_STEPS_PER_UNIT {79.87, 79.87, 2566, 563,78} // Al's TVRR
|
||||
//#define DEFAULT_AXIS_STEPS_PER_UNIT {81.26, 80.01, 2561, 599.14} // Michel TVRR old
|
||||
//#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 739.65} // Michel TVRR
|
||||
#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 600} // David TVRR
|
||||
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 45} // (mm/sec) David TVRR
|
||||
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
|
||||
|
||||
/* MICHEL: This has an impact on the "ripples" in print walls */
|
||||
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
|
||||
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
|
||||
#define DEFAULT_TRAVEL_ACCELERATION 500 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
|
||||
|
||||
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
|
||||
#define DEFAULT_XYJERK 20.0 // (mm/sec)
|
||||
#define DEFAULT_ZJERK 0.4 // (mm/sec)
|
||||
#define DEFAULT_EJERK 5.0 // (mm/sec)
|
||||
|
||||
|
||||
//===========================================================================
|
||||
//============================= Z Probe Options =============================
|
||||
//===========================================================================
|
||||
// @section probes
|
||||
|
||||
//
|
||||
// Probe Type
|
||||
@ -735,30 +760,6 @@
|
||||
#define HOMING_FEEDRATE_XY (50*60)
|
||||
#define HOMING_FEEDRATE_Z (4*60)
|
||||
|
||||
//
|
||||
// MOVEMENT SETTINGS
|
||||
// @section motion
|
||||
//
|
||||
|
||||
// default settings
|
||||
|
||||
//#define DEFAULT_AXIS_STEPS_PER_UNIT {79.87, 79.87, 2566, 563,78} // Al's TVRR
|
||||
//#define DEFAULT_AXIS_STEPS_PER_UNIT {81.26, 80.01, 2561, 599.14} // Michel TVRR old
|
||||
//#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 739.65} // Michel TVRR
|
||||
#define DEFAULT_AXIS_STEPS_PER_UNIT {71.1, 71.1, 2560, 600} // David TVRR
|
||||
#define DEFAULT_MAX_FEEDRATE {500, 500, 5, 45} // (mm/sec) David TVRR
|
||||
#define DEFAULT_MAX_ACCELERATION {9000,9000,100,10000} // X, Y, Z, E maximum start speed for accelerated moves. E default values are good for Skeinforge 40+, for older versions raise them a lot.
|
||||
|
||||
/* MICHEL: This has an impact on the "ripples" in print walls */
|
||||
#define DEFAULT_ACCELERATION 500 // X, Y, Z and E acceleration in mm/s^2 for printing moves
|
||||
#define DEFAULT_RETRACT_ACCELERATION 3000 // E acceleration in mm/s^2 for retracts
|
||||
#define DEFAULT_TRAVEL_ACCELERATION 500 // X, Y, Z acceleration in mm/s^2 for travel (non printing) moves
|
||||
|
||||
// The speed change that does not require acceleration (i.e. the software might assume it can be done instantaneously)
|
||||
#define DEFAULT_XYJERK 20.0 // (mm/sec)
|
||||
#define DEFAULT_ZJERK 0.4 // (mm/sec)
|
||||
#define DEFAULT_EJERK 5.0 // (mm/sec)
|
||||
|
||||
|
||||
//=============================================================================
|
||||
//============================= Additional Features ===========================
|
||||
|
Reference in New Issue
Block a user