Raise the servo probe before stow outside ABL context
This commit is contained in:
		@@ -2327,6 +2327,17 @@ static void homeaxis(AxisEnum axis) {
 | 
			
		||||
        #if ENABLED(DEBUG_LEVELING_FEATURE)
 | 
			
		||||
          if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("> SERVO_ENDSTOPS > Stow with servo.move()");
 | 
			
		||||
        #endif
 | 
			
		||||
        // Raise the servo probe before stow outside ABL context... This is a workaround that allows the use of a Servo Probe without ABL until a more global probe handling is implemented.
 | 
			
		||||
        #if DISABLED(AUTO_BED_LEVELING_FEATURE)
 | 
			
		||||
          #ifndef Z_RAISE_AFTER_PROBING
 | 
			
		||||
            #define Z_RAISE_AFTER_PROBING 15                 // default height
 | 
			
		||||
          #endif
 | 
			
		||||
          current_position[Z_AXIS] = Z_RAISE_AFTER_PROBING;
 | 
			
		||||
          feedrate = homing_feedrate[Z_AXIS];
 | 
			
		||||
          line_to_current_position();
 | 
			
		||||
          stepper.synchronize();
 | 
			
		||||
        #endif
 | 
			
		||||
 | 
			
		||||
        servo[servo_endstop_id[axis]].move(servo_endstop_angle[axis][1]);
 | 
			
		||||
        if (_Z_PROBE_SUBTEST) endstops.enable_z_probe(false);
 | 
			
		||||
      }
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	