Use MANUAL_PROBE_START_Z for UBL manual probing (#20160)

This commit is contained in:
Jason Smith 2020-11-17 21:59:48 -08:00 committed by GitHub
parent caeac3851a
commit 39305aa47c
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23
3 changed files with 8 additions and 4 deletions

View File

@ -62,7 +62,7 @@ class unified_bed_leveling {
#if IS_NEWPANEL #if IS_NEWPANEL
static void move_z_with_encoder(const float &multiplier); static void move_z_with_encoder(const float &multiplier);
static float measure_point_with_encoder(); static float measure_point_with_encoder();
static float measure_business_card_thickness(float in_height); static float measure_business_card_thickness();
static void manually_probe_remaining_mesh(const xy_pos_t&, const float&, const float&, const bool) _O0; static void manually_probe_remaining_mesh(const xy_pos_t&, const float&, const float&, const bool) _O0;
static void fine_tune_mesh(const xy_pos_t &pos, const bool do_ubl_mesh_map) _O0; static void fine_tune_mesh(const xy_pos_t &pos, const bool do_ubl_mesh_map) _O0;
#endif #endif

View File

@ -484,7 +484,7 @@
} }
if (parser.seen('B')) { if (parser.seen('B')) {
g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness(float(Z_CLEARANCE_BETWEEN_PROBES)); g29_card_thickness = parser.has_value() ? parser.value_float() : measure_business_card_thickness();
if (ABS(g29_card_thickness) > 1.5f) { if (ABS(g29_card_thickness) > 1.5f) {
SERIAL_ECHOLNPGM("?Error in Business Card measurement."); SERIAL_ECHOLNPGM("?Error in Business Card measurement.");
return; return;
@ -837,11 +837,11 @@
static void echo_and_take_a_measurement() { SERIAL_ECHOLNPGM(" and take a measurement."); } static void echo_and_take_a_measurement() { SERIAL_ECHOLNPGM(" and take a measurement."); }
float unified_bed_leveling::measure_business_card_thickness(float in_height) { float unified_bed_leveling::measure_business_card_thickness() {
ui.capture(); ui.capture();
save_ubl_active_state_and_disable(); // Disable bed level correction for probing save_ubl_active_state_and_disable(); // Disable bed level correction for probing
do_blocking_move_to(0.5f * (MESH_MAX_X - (MESH_MIN_X)), 0.5f * (MESH_MAX_Y - (MESH_MIN_Y)), in_height); do_blocking_move_to(0.5f * (MESH_MAX_X - (MESH_MIN_X)), 0.5f * (MESH_MAX_Y - (MESH_MIN_Y)), MANUAL_PROBE_START_Z);
//, _MIN(planner.settings.max_feedrate_mm_s[X_AXIS], planner.settings.max_feedrate_mm_s[Y_AXIS]) * 0.5f); //, _MIN(planner.settings.max_feedrate_mm_s[X_AXIS], planner.settings.max_feedrate_mm_s[Y_AXIS]) * 0.5f);
planner.synchronize(); planner.synchronize();

View File

@ -2603,6 +2603,10 @@
#endif #endif
#endif #endif
#if !defined(MANUAL_PROBE_START_Z) && defined(Z_CLEARANCE_BETWEEN_PROBES)
#define MANUAL_PROBE_START_Z Z_CLEARANCE_BETWEEN_PROBES
#endif
#ifndef __SAM3X8E__ //todo: hal: broken hal encapsulation #ifndef __SAM3X8E__ //todo: hal: broken hal encapsulation
#undef UI_VOLTAGE_LEVEL #undef UI_VOLTAGE_LEVEL
#undef RADDS_DISPLAY #undef RADDS_DISPLAY