Merge pull request #3117 from Blue-Marlin/thermal-protection
Improve the descriptions for THERMAL_PROTECTION
This commit is contained in:
		| @@ -280,16 +280,15 @@ Here are some standard links for getting your machine calibrated: | ||||
| //=========================================================================== | ||||
|  | ||||
| /** | ||||
|  * Thermal Runaway Protection protects your printer from damage and fire if a | ||||
|  * Thermal Protection protects your printer from damage and fire if a | ||||
|  * thermistor falls out or temperature sensors fail in any way. | ||||
|  * | ||||
|  * The issue: If a thermistor falls out or a temperature sensor fails, | ||||
|  * Marlin can no longer sense the actual temperature. Since a disconnected | ||||
|  * thermistor reads as a low temperature, the firmware will keep the heater on. | ||||
|  * | ||||
|  * The solution: Once the temperature reaches the target, start observing. | ||||
|  * If the temperature stays too far below the target (hysteresis) for too long, | ||||
|  * the firmware will halt as a safety precaution. | ||||
|  * If you get "Thermal Runaway" or "Heating failed" errors the | ||||
|  * details can be tuned in Configuration_adv.h | ||||
|  */ | ||||
|  | ||||
| #define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders | ||||
|   | ||||
		Reference in New Issue
	