Fix stepper shutdown during waiting for temperatures
In the wait loops of M109 M190 idle() is called, what checks stepper_inactive_time against previous_cmd_ms. Because we can be several minutes inside the loop, resetting previous_cmd_ms only outside the loop caused stepper shutdowns. The name of previous_cmd_ms does not really reflect its use. It's set not only when a new command was received or executed but also in many of the movement routines. For that the little extension of using it during the wait will (hopefully) not hurt. # Conflicts: # Marlin/Configuration_adv.h
This commit is contained in:
		@@ -3975,6 +3975,7 @@ inline void gcode_M109() {
 | 
			
		||||
    }
 | 
			
		||||
 | 
			
		||||
    idle();
 | 
			
		||||
    refresh_cmd_timeout(); // to prevent stepper_inactive_time from running out
 | 
			
		||||
 | 
			
		||||
    #ifdef TEMP_RESIDENCY_TIME
 | 
			
		||||
      // start/restart the TEMP_RESIDENCY_TIME timer whenever we reach target temp for the first time
 | 
			
		||||
@@ -3989,7 +3990,6 @@ inline void gcode_M109() {
 | 
			
		||||
  }
 | 
			
		||||
 | 
			
		||||
  LCD_MESSAGEPGM(MSG_HEATING_COMPLETE);
 | 
			
		||||
  refresh_cmd_timeout();
 | 
			
		||||
  print_job_start_ms = previous_cmd_ms;
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
@@ -4024,9 +4024,9 @@ inline void gcode_M109() {
 | 
			
		||||
        #endif
 | 
			
		||||
      }
 | 
			
		||||
      idle();
 | 
			
		||||
      refresh_cmd_timeout(); // to prevent stepper_inactive_time from running out
 | 
			
		||||
    }
 | 
			
		||||
    LCD_MESSAGEPGM(MSG_BED_DONE);
 | 
			
		||||
    refresh_cmd_timeout();
 | 
			
		||||
  }
 | 
			
		||||
 | 
			
		||||
#endif // HAS_TEMP_BED
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	
	Block a user