Add missing CHAMBER options (for M141) (#13371)
This commit is contained in:
committed by
Scott Lahteine
parent
0375e92847
commit
31ff7da7ac
@ -441,6 +441,8 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -449,6 +451,7 @@
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -459,10 +462,11 @@
|
||||
#define HEATER_3_MAXTEMP 275
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#if ENABLED(BED_AC)
|
||||
#define BED_MAXTEMP 150
|
||||
#define BED_MAXTEMP 150
|
||||
#else
|
||||
#define BED_MAXTEMP 100
|
||||
#define BED_MAXTEMP 100
|
||||
#endif
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -411,6 +411,8 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -420,6 +422,7 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -431,6 +434,7 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|
@ -405,6 +405,8 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -414,6 +416,7 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -425,6 +428,7 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
|