Improve the descriptions for THERMAL_PROTECTION
This commit is contained in:
@ -280,16 +280,15 @@ Here are some standard links for getting your machine calibrated:
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
* Thermal Runaway Protection protects your printer from damage and fire if a
|
||||
* Thermal Protection protects your printer from damage and fire if a
|
||||
* thermistor falls out or temperature sensors fail in any way.
|
||||
*
|
||||
* The issue: If a thermistor falls out or a temperature sensor fails,
|
||||
* Marlin can no longer sense the actual temperature. Since a disconnected
|
||||
* thermistor reads as a low temperature, the firmware will keep the heater on.
|
||||
*
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long,
|
||||
* the firmware will halt as a safety precaution.
|
||||
* If you get "Thermal Runaway" or "Heating failed" errors the
|
||||
* details can be tuned in Configuration_adv.h
|
||||
*/
|
||||
|
||||
#define THERMAL_PROTECTION_HOTENDS // Enable thermal protection for all extruders
|
||||
|
@ -17,6 +17,20 @@
|
||||
/**
|
||||
* Thermal Protection parameters
|
||||
*/
|
||||
/**
|
||||
* Thermal Protection protects your printer from damage and fire if a
|
||||
* thermistor falls out or temperature sensors fail in any way.
|
||||
*
|
||||
* The issue: If a thermistor falls out or a temperature sensor fails,
|
||||
* Marlin can no longer sense the actual temperature. Since a disconnected
|
||||
* thermistor reads as a low temperature, the firmware will keep the heater on.
|
||||
*
|
||||
* The solution: Once the temperature reaches the target, start observing.
|
||||
* If the temperature stays too far below the target (hysteresis) for too long (period),
|
||||
* the firmware will halt the machine as a safety precaution.
|
||||
*
|
||||
* If you get false positives for "Thermal Runaway" increase THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
|
||||
*/
|
||||
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
|
||||
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
|
||||
#define THERMAL_PROTECTION_HYSTERESIS 4 // Degrees Celsius
|
||||
@ -26,11 +40,19 @@
|
||||
* WATCH_TEMP_PERIOD to expire, and if the temperature hasn't increased by WATCH_TEMP_INCREASE
|
||||
* degrees, the machine is halted, requiring a hard reset. This test restarts with any M104/M109,
|
||||
* but only if the current temperature is far enough below the target for a reliable test.
|
||||
*
|
||||
* If you get false positives for "Heating failed" increase WATCH_TEMP_PERIOD and/or decrease WATCH_TEMP_INCREASE
|
||||
* WATCH_TEMP_INCREASE should not be below 2.
|
||||
*/
|
||||
#define WATCH_TEMP_PERIOD 16 // Seconds
|
||||
#define WATCH_TEMP_INCREASE 4 // Degrees Celsius
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Thermal Protection parameters for the bed
|
||||
* are like the above for the hotends.
|
||||
* WATCH_TEMP_BED_PERIOD and WATCH_TEMP_BED_INCREASE are not imlemented now.
|
||||
*/
|
||||
#if ENABLED(THERMAL_PROTECTION_BED)
|
||||
#define THERMAL_PROTECTION_BED_PERIOD 20 // Seconds
|
||||
#define THERMAL_PROTECTION_BED_HYSTERESIS 2 // Degrees Celsius
|
||||
|