Added Fan control to the pre-heat settings.

I find that the PID routine works better when the cooling fan is switched on
at the beginning of a warm up routine.  Otherwise when you enable the fan
just before a print, you have a delay as the PIDre-adjusts.

This should also be safer as most cooling fans are directed at the hot -ends
thermal barrier!
This commit is contained in:
Blair Thompson
2012-02-22 23:05:52 +00:00
parent d9f2f509d5
commit 2fd8c248fe
2 changed files with 8 additions and 2 deletions

View File

@ -194,10 +194,16 @@ const bool Z_ENDSTOPS_INVERTING = false; // set to true to invert the logic of t
#define ULTRA_LCD
#define LCD_WIDTH 20
#define LCD_HEIGHT 4
// Preheat Constants
#define PLA_PREHEAT_HOTEND_TEMP 180
#define PLA_PREHEAT_HPB_TEMP 70
#define PLA_PREHEAT_FAN_SPEED 255 // Insert Value between 0 and 255
#define ABS_PREHEAT_HOTEND_TEMP 240
#define ABS_PREHEAT_HPB_TEMP 100
#define ABS_PREHEAT_FAN_SPEED 255 // Insert Value between 0 and 255
#else //no panel but just lcd
#ifdef ULTRA_LCD
#define LCD_WIDTH 16