Update Thermal Protection Documentation
This commit is contained in:
@ -428,12 +428,13 @@
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
* Thermal Protection protects your printer from damage and fire if a
|
||||
* thermistor falls out or temperature sensors fail in any way.
|
||||
* Thermal Protection provides additional protection to your printer from damage
|
||||
* and fire. Marlin always includes safe min and max temperature ranges which
|
||||
* protect against a broken or disconnected thermistor wire.
|
||||
*
|
||||
* The issue: If a thermistor falls out or a temperature sensor fails,
|
||||
* Marlin can no longer sense the actual temperature. Since a disconnected
|
||||
* thermistor reads as a low temperature, the firmware will keep the heater on.
|
||||
* The issue: If a thermistor falls out, it will report the much lower
|
||||
* temperature of the air in the room, and the the firmware will keep
|
||||
* the heater on.
|
||||
*
|
||||
* If you get "Thermal Runaway" or "Heating failed" errors the
|
||||
* details can be tuned in Configuration_adv.h
|
||||
|