Add Chamber servo vent, auto fan (#19519)
This commit is contained in:
committed by
Scott Lahteine
parent
6fcbf11454
commit
2b845e5a75
@ -32,11 +32,10 @@
|
||||
*/
|
||||
#define CONFIGURATION_ADV_H_VERSION 020007
|
||||
|
||||
// @section temperature
|
||||
|
||||
//===========================================================================
|
||||
//============================= Thermal Settings ============================
|
||||
//===========================================================================
|
||||
// @section temperature
|
||||
|
||||
/**
|
||||
* Thermocouple sensors are quite sensitive to noise. Any noise induced in
|
||||
@ -125,9 +124,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
//
|
||||
// Heated Bed Bang-Bang options
|
||||
//
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // (ms) Interval between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
#define BED_HYSTERESIS 2 // (°C) Only set the relevant heater state when ABS(T-target) > BED_HYSTERESIS
|
||||
#endif
|
||||
#endif
|
||||
|
||||
//
|
||||
// Heated Chamber options
|
||||
//
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
@ -135,12 +144,28 @@
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
#define BED_HYSTERESIS 2 // Only disable heating if T>target+BED_HYSTERESIS and enable heating if T>target-BED_HYSTERESIS
|
||||
//#define CHAMBER_FAN // Enable a fan on the chamber
|
||||
#if ENABLED(CHAMBER_FAN)
|
||||
#define CHAMBER_FAN_MODE 2 // Fan control mode: 0=Static; 1=Linear increase when temp is higher than target; 2=V-shaped curve.
|
||||
#if CHAMBER_FAN_MODE == 0
|
||||
#define CHAMBER_FAN_BASE 255 // Chamber fan PWM (0-255)
|
||||
#elif CHAMBER_FAN_MODE == 1
|
||||
#define CHAMBER_FAN_BASE 128 // Base chamber fan PWM (0-255); turns on when chamber temperature is above the target
|
||||
#define CHAMBER_FAN_FACTOR 25 // PWM increase per °C above target
|
||||
#elif CHAMBER_FAN_MODE == 2
|
||||
#define CHAMBER_FAN_BASE 128 // Minimum chamber fan PWM (0-255)
|
||||
#define CHAMBER_FAN_FACTOR 25 // PWM increase per °C difference from target
|
||||
#endif
|
||||
#endif
|
||||
|
||||
//#define CHAMBER_VENT // Enable a servo-controlled vent on the chamber
|
||||
#if ENABLED(CHAMBER_VENT)
|
||||
#define CHAMBER_VENT_SERVO_NR 1 // Index of the vent servo
|
||||
#define HIGH_EXCESS_HEAT_LIMIT 5 // How much above target temp to consider there is excess heat in the chamber
|
||||
#define LOW_EXCESS_HEAT_LIMIT 3
|
||||
#define MIN_COOLING_SLOPE_TIME_CHAMBER_VENT 20
|
||||
#define MIN_COOLING_SLOPE_DEG_CHAMBER_VENT 1.5
|
||||
#endif
|
||||
#endif
|
||||
|
||||
|