[2.0.x] Add Z_AFTER_PROBING option (#10058)
Some "fix-mounted" probes need manual stowing. And after probing some may prefer to raise or lower the nozzle. This restores an old option but tailors it to allow raise or lower as preferred.
This commit is contained in:
@ -162,7 +162,7 @@
|
||||
#elif defined(MIN_Z_HEIGHT_FOR_HOMING)
|
||||
#error "MIN_Z_HEIGHT_FOR_HOMING is now Z_HOMING_HEIGHT. Please update your configuration."
|
||||
#elif defined(Z_RAISE_BEFORE_PROBING) || defined(Z_RAISE_AFTER_PROBING)
|
||||
#error "Z_RAISE_(BEFORE|AFTER)_PROBING are deprecated. Use Z_CLEARANCE_DEPLOY_PROBE instead."
|
||||
#error "Z_RAISE_(BEFORE|AFTER)_PROBING are deprecated. Use Z_CLEARANCE_DEPLOY_PROBE and Z_AFTER_PROBING instead."
|
||||
#elif defined(Z_RAISE_PROBE_DEPLOY_STOW) || defined(Z_RAISE_BETWEEN_PROBINGS)
|
||||
#error "Z_RAISE_PROBE_DEPLOY_STOW and Z_RAISE_BETWEEN_PROBINGS are now Z_CLEARANCE_DEPLOY_PROBE and Z_CLEARANCE_BETWEEN_PROBES. Please update your configuration."
|
||||
#elif defined(Z_PROBE_DEPLOY_HEIGHT) || defined(Z_PROBE_TRAVEL_HEIGHT)
|
||||
@ -789,6 +789,8 @@ static_assert(1 >= 0
|
||||
#error "Probes need Z_CLEARANCE_DEPLOY_PROBE >= 0."
|
||||
#elif Z_CLEARANCE_BETWEEN_PROBES < 0
|
||||
#error "Probes need Z_CLEARANCE_BETWEEN_PROBES >= 0."
|
||||
#elif Z_AFTER_PROBING < 0
|
||||
#error "Probes need Z_AFTER_PROBING >= 0."
|
||||
#endif
|
||||
|
||||
#if MULTIPLE_PROBING && MULTIPLE_PROBING < 2
|
||||
|
Reference in New Issue
Block a user