Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x. Chamber temperature is currently reported along with hot end and bed temperatures to serial. The format is just like that used for hot end and bed temperatures, but using 'C' prefix. As there is no heater, target is always 0. Is this appropriate, is there a better way to report chamber temperatures? Chamber temperatures are not reported on the LCD in any way. When auto chamber fan is enabled, it currently just uses the same temperature threshold as the other auto controlled fans. As the chamber temperature is not connected to any heater, it doesn't undergo mintemp/maxtemp monitoring. This would need to change in the future if chamber heating became a feature.
This commit is contained in:
@ -389,6 +389,15 @@
|
||||
#define BED_USES_THERMISTOR
|
||||
#endif
|
||||
|
||||
#if TEMP_SENSOR_CHAMBER <= -2
|
||||
#error "MAX6675 / MAX31855 Thermocouples not supported for TEMP_SENSOR_CHAMBER"
|
||||
#elif TEMP_SENSOR_CHAMBER == -1
|
||||
#define CHAMBER_USES_AD595
|
||||
#elif TEMP_SENSOR_CHAMBER > 0
|
||||
#define THERMISTORCHAMBER TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_USES_THERMISTOR
|
||||
#endif
|
||||
|
||||
#ifdef __SAM3X8E__
|
||||
#define HEATER_USES_AD595 (ENABLED(HEATER_0_USES_AD595) || ENABLED(HEATER_1_USES_AD595) || ENABLED(HEATER_2_USES_AD595) || ENABLED(HEATER_3_USES_AD595))
|
||||
#endif
|
||||
@ -754,7 +763,8 @@
|
||||
#define HAS_TEMP_4 (PIN_EXISTS(TEMP_4) && TEMP_SENSOR_4 != 0 && TEMP_SENSOR_4 > -2)
|
||||
#define HAS_TEMP_HOTEND (HAS_TEMP_0 || ENABLED(HEATER_0_USES_MAX6675))
|
||||
#define HAS_TEMP_BED (PIN_EXISTS(TEMP_BED) && TEMP_SENSOR_BED != 0 && TEMP_SENSOR_BED > -2)
|
||||
#define HAS_TEMP_SENSOR (HAS_TEMP_HOTEND || HAS_TEMP_BED)
|
||||
#define HAS_TEMP_CHAMBER (PIN_EXISTS(TEMP_CHAMBER) && TEMP_SENSOR_CHAMBER != 0 && TEMP_SENSOR_CHAMBER > -2)
|
||||
#define HAS_TEMP_SENSOR (HAS_TEMP_HOTEND || HAS_TEMP_BED || HAS_TEMP_CHAMBER)
|
||||
|
||||
// Heaters
|
||||
#define HAS_HEATER_0 (PIN_EXISTS(HEATER_0))
|
||||
@ -775,7 +785,8 @@
|
||||
#define HAS_AUTO_FAN_2 (HOTENDS > 2 && PIN_EXISTS(E2_AUTO_FAN))
|
||||
#define HAS_AUTO_FAN_3 (HOTENDS > 3 && PIN_EXISTS(E3_AUTO_FAN))
|
||||
#define HAS_AUTO_FAN_4 (HOTENDS > 4 && PIN_EXISTS(E4_AUTO_FAN))
|
||||
#define HAS_AUTO_FAN (HAS_AUTO_FAN_0 || HAS_AUTO_FAN_1 || HAS_AUTO_FAN_2 || HAS_AUTO_FAN_3)
|
||||
#define HAS_AUTO_CHAMBER_FAN (PIN_EXISTS(CHAMBER_AUTO_FAN))
|
||||
#define HAS_AUTO_FAN (HAS_AUTO_FAN_0 || HAS_AUTO_FAN_1 || HAS_AUTO_FAN_2 || HAS_AUTO_FAN_3 || HAS_AUTO_CHAMBER_FAN)
|
||||
#define AUTO_1_IS_0 (E1_AUTO_FAN_PIN == E0_AUTO_FAN_PIN)
|
||||
#define AUTO_2_IS_0 (E2_AUTO_FAN_PIN == E0_AUTO_FAN_PIN)
|
||||
#define AUTO_2_IS_1 (E2_AUTO_FAN_PIN == E1_AUTO_FAN_PIN)
|
||||
@ -786,6 +797,11 @@
|
||||
#define AUTO_4_IS_1 (E4_AUTO_FAN_PIN == E1_AUTO_FAN_PIN)
|
||||
#define AUTO_4_IS_2 (E4_AUTO_FAN_PIN == E2_AUTO_FAN_PIN)
|
||||
#define AUTO_4_IS_3 (E4_AUTO_FAN_PIN == E3_AUTO_FAN_PIN)
|
||||
#define AUTO_CHAMBER_IS_0 (CHAMBER_AUTO_FAN_PIN == E0_AUTO_FAN_PIN)
|
||||
#define AUTO_CHAMBER_IS_1 (CHAMBER_AUTO_FAN_PIN == E1_AUTO_FAN_PIN)
|
||||
#define AUTO_CHAMBER_IS_2 (CHAMBER_AUTO_FAN_PIN == E2_AUTO_FAN_PIN)
|
||||
#define AUTO_CHAMBER_IS_3 (CHAMBER_AUTO_FAN_PIN == E3_AUTO_FAN_PIN)
|
||||
#define AUTO_CHAMBER_IS_4 (CHAMBER_AUTO_FAN_PIN == E4_AUTO_FAN_PIN)
|
||||
|
||||
// Other fans
|
||||
#define HAS_FAN0 (PIN_EXISTS(FAN))
|
||||
|