Tweaks to heater / lcd conditions

This commit is contained in:
Scott Lahteine
2018-05-13 03:08:55 -05:00
parent 9d98a62699
commit 083ec9963e
4 changed files with 33 additions and 30 deletions

View File

@ -1126,7 +1126,9 @@ void Temperature::init() {
inited = true;
#endif
#if MB(RUMBA) && (TEMP_SENSOR_0 == -1 || TEMP_SENSOR_1 == -1 || TEMP_SENSOR_2 == -1 || TEMP_SENSOR_BED == -1 || TEMP_SENSOR_CHAMBER == -1)
#if MB(RUMBA) && ( \
ENABLED(HEATER_0_USES_AD595) || ENABLED(HEATER_1_USES_AD595) || ENABLED(HEATER_2_USES_AD595) || ENABLED(HEATER_3_USES_AD595) || ENABLED(HEATER_4_USES_AD595) || ENABLED(HEATER_BED_USES_AD595) || ENABLED(HEATER_CHAMBER_USES_AD595) \
|| ENABLED(HEATER_0_USES_AD8495) || ENABLED(HEATER_1_USES_AD8495) || ENABLED(HEATER_2_USES_AD8495) || ENABLED(HEATER_3_USES_AD8495) || ENABLED(HEATER_4_USES_AD8495) || ENABLED(HEATER_BED_USES_AD8495) || ENABLED(HEATER_CHAMBER_USES_AD8495))
// Disable RUMBA JTAG in case the thermocouple extension is plugged on top of JTAG connector
MCUCR = _BV(JTD);
MCUCR = _BV(JTD);