Update LCD timing on Formbot T-Rex 2+ machines
The code is slightly more optimized than it used to be and this has caused the setup and hold times on the Formbot T-Rex 2+ machines to be insufficient. This change gives sufficient margin and the LCD Display is clean again.
This commit is contained in:
		@@ -21,6 +21,15 @@
 | 
			
		||||
 */
 | 
			
		||||
#pragma once
 | 
			
		||||
 | 
			
		||||
/**
 | 
			
		||||
 * Override default LCD timing for Formbot T-Rex 2+ machines.
 | 
			
		||||
 * The long LCD cables and the routing near electrically noisy stepper motors
 | 
			
		||||
 * requires a slightly longer setup and hold time on the signals.
 | 
			
		||||
 */
 | 
			
		||||
#define BOARD_ST7920_DELAY_1 DELAY_NS(200)
 | 
			
		||||
#define BOARD_ST7920_DELAY_2 DELAY_NS(200)
 | 
			
		||||
#define BOARD_ST7920_DELAY_3 DELAY_NS(200)
 | 
			
		||||
 | 
			
		||||
/**
 | 
			
		||||
 * Formbot pin assignments
 | 
			
		||||
 */
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	