Fix MAX31865 on SPI (PT100/1000) support (#20074)
This commit is contained in:
committed by
Scott Lahteine
parent
012745b218
commit
02c3c314fe
@ -436,11 +436,11 @@
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
#define DUMMY_THERMISTOR_999_VALUE 100
|
||||
|
||||
// Resistor values when using a MAX31865 (sensor -5)
|
||||
// Sensor value is typically 100 (PT100) or 1000 (PT1000)
|
||||
// Calibration value is typically 430 ohm for AdaFruit PT100 modules and 4300 ohm for AdaFruit PT1000 modules.
|
||||
//#define MAX31865_SENSOR_OHMS 100
|
||||
//#define MAX31865_CALIBRATION_OHMS 430
|
||||
// Resistor values when using MAX31865 sensors (-5) on TEMP_SENSOR_0 / 1
|
||||
//#define MAX31865_SENSOR_OHMS_0 100 // (Ω) Typically 100 or 1000 (PT100 or PT1000)
|
||||
//#define MAX31865_CALIBRATION_OHMS_0 430 // (Ω) Typically 430 for AdaFruit PT100; 4300 for AdaFruit PT1000
|
||||
//#define MAX31865_SENSOR_OHMS_1 100
|
||||
//#define MAX31865_CALIBRATION_OHMS_1 430
|
||||
|
||||
// Use temp sensor 1 as a redundant sensor with sensor 0. If the readings
|
||||
// from the two sensors differ too much the print will be aborted.
|
||||
|
Reference in New Issue