Marlin_Firmware/Marlin/SanityCheck.h

390 lines
13 KiB
C
Raw Normal View History

/**
* SanityCheck.h
*
* Test configuration values for errors at compile-time.
*/
#ifndef SANITYCHECK_H
#define SANITYCHECK_H
/**
* Dual Stepper Drivers
*/
#if ENABLED(Z_DUAL_STEPPER_DRIVERS) && ENABLED(Y_DUAL_STEPPER_DRIVERS)
#error You cannot have dual stepper drivers for both Y and Z.
#endif
/**
* Progress Bar
*/
#if ENABLED(LCD_PROGRESS_BAR)
#if DISABLED(SDSUPPORT)
#error LCD_PROGRESS_BAR requires SDSUPPORT.
#endif
#if ENABLED(DOGLCD)
#error LCD_PROGRESS_BAR does not apply to graphical displays.
#endif
#if ENABLED(FILAMENT_LCD_DISPLAY)
#error LCD_PROGRESS_BAR and FILAMENT_LCD_DISPLAY are not fully compatible. Comment out this line to use both.
#endif
#endif
/**
* Babystepping
*/
#if ENABLED(BABYSTEPPING)
#if ENABLED(COREXY)
#error BABYSTEPPING not implemented for COREXY yet.
#endif
#if ENABLED(SCARA)
#error BABYSTEPPING is not implemented for SCARA yet.
#endif
#if ENABLED(DELTA) && ENABLED(BABYSTEP_XY)
#error BABYSTEPPING only implemented for Z axis on deltabots.
#endif
#endif
/**
* Filament Change with Extruder Runout Prevention
*/
#if ENABLED(FILAMENTCHANGEENABLE) && ENABLED(EXTRUDER_RUNOUT_PREVENT)
#error EXTRUDER_RUNOUT_PREVENT currently incompatible with FILAMENTCHANGE.
#endif
/**
2015-07-24 17:53:14 -05:00
* Options only for EXTRUDERS > 1
*/
#if EXTRUDERS > 1
#if EXTRUDERS > 4
2015-04-03 17:31:35 -05:00
#error The maximum number of EXTRUDERS in Marlin is 4.
#endif
#if ENABLED(TEMP_SENSOR_1_AS_REDUNDANT)
#error EXTRUDERS must be 1 with TEMP_SENSOR_1_AS_REDUNDANT.
#endif
#if ENABLED(HEATERS_PARALLEL)
#error EXTRUDERS must be 1 with HEATERS_PARALLEL.
#endif
#if ENABLED(Y_DUAL_STEPPER_DRIVERS)
#error EXTRUDERS must be 1 with Y_DUAL_STEPPER_DRIVERS.
#endif
#if ENABLED(Z_DUAL_STEPPER_DRIVERS)
#error EXTRUDERS must be 1 with Z_DUAL_STEPPER_DRIVERS.
#endif
#endif // EXTRUDERS > 1
2015-04-03 17:31:35 -05:00
/**
* Limited number of servos
*/
#if NUM_SERVOS > 4
#error The maximum number of SERVOS in Marlin is 4.
#endif
#if defined(NUM_SERVOS) && NUM_SERVOS > 0
#if X_ENDSTOP_SERVO_NR >= 0 || Y_ENDSTOP_SERVO_NR >= 0 || Z_ENDSTOP_SERVO_NR >= 0
#if X_ENDSTOP_SERVO_NR >= NUM_SERVOS
#error X_ENDSTOP_SERVO_NR must be smaller than NUM_SERVOS.
#elif Y_ENDSTOP_SERVO_NR >= NUM_SERVOS
#error Y_ENDSTOP_SERVO_NR must be smaller than NUM_SERVOS.
#elif Z_ENDSTOP_SERVO_NR >= NUM_SERVOS
#error Z_ENDSTOP_SERVO_NR must be smaller than NUM_SERVOS.
#endif
#endif
#endif
2015-04-03 17:31:35 -05:00
/**
* Servo deactivation depends on servo endstops
*/
#if ENABLED(DEACTIVATE_SERVOS_AFTER_MOVE) && !HAS_SERVO_ENDSTOPS
#error At least one of the ?_ENDSTOP_SERVO_NR is required for DEACTIVATE_SERVOS_AFTER_MOVE.
#endif
/**
* Required LCD language
*/
#if DISABLED(DOGLCD) && ENABLED(ULTRA_LCD) && DISABLED(DISPLAY_CHARSET_HD44780_JAPAN) && DISABLED(DISPLAY_CHARSET_HD44780_WESTERN) && DISABLED(DISPLAY_CHARSET_HD44780_CYRILLIC)
#error You must enable either DISPLAY_CHARSET_HD44780_JAPAN or DISPLAY_CHARSET_HD44780_WESTERN or DISPLAY_CHARSET_HD44780_CYRILLIC for your LCD controller.
#endif
/**
* Mesh Bed Leveling
*/
#if ENABLED(MESH_BED_LEVELING)
#if ENABLED(DELTA)
#error MESH_BED_LEVELING does not yet support DELTA printers.
#endif
#if ENABLED(ENABLE_AUTO_BED_LEVELING)
#error Select ENABLE_AUTO_BED_LEVELING or MESH_BED_LEVELING, not both.
#endif
#if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
#error MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8.
#endif
#endif
/**
* Auto Bed Leveling
*/
#if ENABLED(ENABLE_AUTO_BED_LEVELING)
/**
* Require a Z Min pin
*/
#if Z_MIN_PIN == -1
#if Z_PROBE_PIN == -1 || (DISABLED(Z_PROBE_ENDSTOP) || ENABLED(DISABLE_Z_PROBE_ENDSTOP)) // It's possible for someone to set a pin for the Z Probe, but not enable it.
#if ENABLED(Z_PROBE_REPEATABILITY_TEST)
#error You must have a Z_MIN or Z_PROBE endstop to enable Z_PROBE_REPEATABILITY_TEST.
#else
#error ENABLE_AUTO_BED_LEVELING requires a Z_MIN or Z_PROBE endstop. Z_MIN_PIN or Z_PROBE_PIN must point to a valid hardware pin.
#endif
#endif
#endif
/**
* Require a Z Probe Pin if Z_PROBE_ENDSTOP is enabled.
*/
#if ENABLED(Z_PROBE_ENDSTOP)
#ifndef Z_PROBE_PIN
#error You must have a Z_PROBE_PIN defined in your pins_XXXX.h file if you enable Z_PROBE_ENDSTOP.
#endif
#if Z_PROBE_PIN == -1
#error You must set Z_PROBE_PIN to a valid pin if you enable Z_PROBE_ENDSTOP.
#endif
// Forcing Servo definitions can break some hall effect sensor setups. Leaving these here for further comment.
// #ifndef NUM_SERVOS
// #error You must have NUM_SERVOS defined and there must be at least 1 configured to use Z_PROBE_ENDSTOP.
// #endif
// #if defined(NUM_SERVOS) && NUM_SERVOS < 1
// #error You must have at least 1 servo defined for NUM_SERVOS to use Z_PROBE_ENDSTOP.
// #endif
// #if Z_ENDSTOP_SERVO_NR < 0
// #error You must have Z_ENDSTOP_SERVO_NR set to at least 0 or above to use Z_PROBE_ENDSTOP.
// #endif
// #ifndef SERVO_ENDSTOP_ANGLES
// #error You must have SERVO_ENDSTOP_ANGLES defined for Z Extend and Retract to use Z_PROBE_ENDSTOP.
2015-04-01 12:13:25 -05:00
// #endif
#endif
/**
* Check if Probe_Offset * Grid Points is greater than Probing Range
*/
#if ENABLED(AUTO_BED_LEVELING_GRID)
#ifndef DELTA_PROBABLE_RADIUS
// Be sure points are in the right order
#if LEFT_PROBE_BED_POSITION > RIGHT_PROBE_BED_POSITION
#error LEFT_PROBE_BED_POSITION must be less than RIGHT_PROBE_BED_POSITION.
#elif FRONT_PROBE_BED_POSITION > BACK_PROBE_BED_POSITION
#error BACK_PROBE_BED_POSITION must be less than FRONT_PROBE_BED_POSITION.
#endif
// Make sure probing points are reachable
#if LEFT_PROBE_BED_POSITION < MIN_PROBE_X
#error "The given LEFT_PROBE_BED_POSITION can't be reached by the probe."
#elif RIGHT_PROBE_BED_POSITION > MAX_PROBE_X
#error "The given RIGHT_PROBE_BED_POSITION can't be reached by the probe."
#elif FRONT_PROBE_BED_POSITION < MIN_PROBE_Y
#error "The given FRONT_PROBE_BED_POSITION can't be reached by the probe."
#elif BACK_PROBE_BED_POSITION > MAX_PROBE_Y
#error "The given BACK_PROBE_BED_POSITION can't be reached by the probe."
#endif
#endif
#else // !AUTO_BED_LEVELING_GRID
// Check the triangulation points
#if ABL_PROBE_PT_1_X < MIN_PROBE_X || ABL_PROBE_PT_1_X > MAX_PROBE_X
#error "The given ABL_PROBE_PT_1_X can't be reached by the probe."
#elif ABL_PROBE_PT_2_X < MIN_PROBE_X || ABL_PROBE_PT_2_X > MAX_PROBE_X
#error "The given ABL_PROBE_PT_2_X can't be reached by the probe."
#elif ABL_PROBE_PT_3_X < MIN_PROBE_X || ABL_PROBE_PT_3_X > MAX_PROBE_X
#error "The given ABL_PROBE_PT_3_X can't be reached by the probe."
#elif ABL_PROBE_PT_1_Y < MIN_PROBE_Y || ABL_PROBE_PT_1_Y > MAX_PROBE_Y
#error "The given ABL_PROBE_PT_1_Y can't be reached by the probe."
#elif ABL_PROBE_PT_2_Y < MIN_PROBE_Y || ABL_PROBE_PT_2_Y > MAX_PROBE_Y
#error "The given ABL_PROBE_PT_2_Y can't be reached by the probe."
#elif ABL_PROBE_PT_3_Y < MIN_PROBE_Y || ABL_PROBE_PT_3_Y > MAX_PROBE_Y
#error "The given ABL_PROBE_PT_3_Y can't be reached by the probe."
#endif
#endif // !AUTO_BED_LEVELING_GRID
#endif // ENABLE_AUTO_BED_LEVELING
/**
* ULTIPANEL encoder
*/
#if ENABLED(ULTIPANEL) && DISABLED(NEWPANEL) && DISABLED(SR_LCD_2W_NL) && !defined(SHIFT_CLK)
#error ULTIPANEL requires some kind of encoder.
#endif
/**
* Delta has limited bed leveling options
*/
#if ENABLED(DELTA)
#if ENABLED(ENABLE_AUTO_BED_LEVELING)
#if DISABLED(AUTO_BED_LEVELING_GRID)
#error Only AUTO_BED_LEVELING_GRID is supported with DELTA.
#endif
#if ENABLED(Z_PROBE_SLED)
#error You cannot use Z_PROBE_SLED with DELTA.
#endif
#if ENABLED(Z_PROBE_REPEATABILITY_TEST)
#error Z_PROBE_REPEATABILITY_TEST is not supported with DELTA yet.
#endif
#endif
#endif
/**
* Allen Key Z Probe requires Auto Bed Leveling grid and Delta
*/
#if ENABLED(Z_PROBE_ALLEN_KEY) && !(ENABLED(AUTO_BED_LEVELING_GRID) && ENABLED(DELTA))
#error Invalid use of Z_PROBE_ALLEN_KEY.
#endif
/**
* Dual X Carriage requirements
*/
#if ENABLED(DUAL_X_CARRIAGE)
#if EXTRUDERS == 1 || ENABLED(COREXY) \
2015-04-03 17:31:35 -05:00
|| !HAS_X2_ENABLE || !HAS_X2_STEP || !HAS_X2_DIR \
|| !defined(X2_HOME_POS) || !defined(X2_MIN_POS) || !defined(X2_MAX_POS) \
2015-04-03 17:31:35 -05:00
|| !HAS_X_MAX
#error Missing or invalid definitions for DUAL_X_CARRIAGE mode.
#endif
#if X_HOME_DIR != -1 || X2_HOME_DIR != 1
#error Please use canonical x-carriage assignment.
#endif
#endif // DUAL_X_CARRIAGE
/**
* Make sure auto fan pins don't conflict with the fan pin
*/
#if HAS_AUTO_FAN && HAS_FAN
#if EXTRUDER_0_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_0_AUTO_FAN_PIN equal to FAN_PIN.
#elif EXTRUDER_1_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_1_AUTO_FAN_PIN equal to FAN_PIN.
#elif EXTRUDER_2_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_2_AUTO_FAN_PIN equal to FAN_PIN.
#elif EXTRUDER_3_AUTO_FAN_PIN == FAN_PIN
#error You cannot set EXTRUDER_3_AUTO_FAN_PIN equal to FAN_PIN.
#endif
#endif
2015-04-03 17:31:35 -05:00
#if HAS_FAN && CONTROLLERFAN_PIN == FAN_PIN
#error You cannot set CONTROLLERFAN_PIN equal to FAN_PIN.
2015-04-03 17:31:35 -05:00
#endif
/**
* Test Heater, Temp Sensor, and Extruder Pins; Sensor Type must also be set.
*/
#if EXTRUDERS > 3
#if !HAS_HEATER_3
#error HEATER_3_PIN not defined for this board.
#elif !PIN_EXISTS(TEMP_3)
#error TEMP_3_PIN not defined for this board.
#elif !PIN_EXISTS(E3_STEP) || !PIN_EXISTS(E3_DIR) || !PIN_EXISTS(E3_ENABLE)
#error E3_STEP_PIN, E3_DIR_PIN, or E3_ENABLE_PIN not defined for this board.
2015-07-24 17:53:14 -05:00
#elif TEMP_SENSOR_3 == 0
#error TEMP_SENSOR_3 is required with 4 EXTRUDERS.
#endif
#elif EXTRUDERS > 2
#if !HAS_HEATER_2
#error HEATER_2_PIN not defined for this board.
#elif !PIN_EXISTS(TEMP_2)
#error TEMP_2_PIN not defined for this board.
#elif !PIN_EXISTS(E2_STEP) || !PIN_EXISTS(E2_DIR) || !PIN_EXISTS(E2_ENABLE)
#error E2_STEP_PIN, E2_DIR_PIN, or E2_ENABLE_PIN not defined for this board.
2015-07-24 17:53:14 -05:00
#elif TEMP_SENSOR_2 == 0
2015-07-24 18:01:27 -05:00
#error TEMP_SENSOR_2 is required with 3 or more EXTRUDERS.
#endif
#elif EXTRUDERS > 1
#if !PIN_EXISTS(TEMP_1)
#error TEMP_1_PIN not defined for this board.
#elif !PIN_EXISTS(E1_STEP) || !PIN_EXISTS(E1_DIR) || !PIN_EXISTS(E1_ENABLE)
#error E1_STEP_PIN, E1_DIR_PIN, or E1_ENABLE_PIN not defined for this board.
#endif
#endif
#if EXTRUDERS > 1 || ENABLED(HEATERS_PARALLEL)
#if !HAS_HEATER_1
#error HEATER_1_PIN not defined for this board.
#endif
#endif
2015-07-24 18:01:27 -05:00
#if TEMP_SENSOR_1 == 0
#if EXTRUDERS > 1
#error TEMP_SENSOR_1 is required with 2 or more EXTRUDERS.
#elif ENABLED(TEMP_SENSOR_1_AS_REDUNDANT)
#error TEMP_SENSOR_1 is required with TEMP_SENSOR_1_AS_REDUNDANT.
#endif
#endif
#if !HAS_HEATER_0
#error HEATER_0_PIN not defined for this board.
#elif !PIN_EXISTS(TEMP_0)
#error TEMP_0_PIN not defined for this board.
#elif !PIN_EXISTS(E0_STEP) || !PIN_EXISTS(E0_DIR) || !PIN_EXISTS(E0_ENABLE)
#error E0_STEP_PIN, E0_DIR_PIN, or E0_ENABLE_PIN not defined for this board.
#elif TEMP_SENSOR_0 == 0
2015-07-24 17:53:14 -05:00
#error TEMP_SENSOR_0 is required.
#endif
2015-04-03 17:31:35 -05:00
/**
* Warnings for old configurations
*/
#ifdef X_HOME_RETRACT_MM
#error [XYZ]_HOME_RETRACT_MM settings have been renamed [XYZ]_HOME_BUMP_MM.
2015-04-03 17:31:35 -05:00
#endif
#if WATCH_TEMP_PERIOD > 500
#error WATCH_TEMP_PERIOD now uses seconds instead of milliseconds.
#endif
#if DISABLED(THERMAL_PROTECTION_HOTENDS) && (defined(WATCH_TEMP_PERIOD) || defined(THERMAL_PROTECTION_PERIOD))
#error Thermal Runaway Protection for hotends must now be enabled with THERMAL_PROTECTION_HOTENDS.
#endif
#if DISABLED(THERMAL_PROTECTION_BED) && defined(THERMAL_PROTECTION_BED_PERIOD)
#error Thermal Runaway Protection for the bed must now be enabled with THERMAL_PROTECTION_BED.
2015-05-11 00:58:37 -05:00
#endif
#ifdef PROBE_SERVO_DEACTIVATION_DELAY
#error PROBE_SERVO_DEACTIVATION_DELAY has been replaced with DEACTIVATE_SERVOS_AFTER_MOVE and SERVO_DEACTIVATION_DELAY.
#endif
#if defined(COREXZ) && defined(Z_LATE_ENABLE)
#error "Z_LATE_ENABLE can't be used with COREXZ."
#endif
#ifdef BEEPER
#error BEEPER has been replaced with BEEPER_PIN. Please update your pins definitions.
#endif
2015-07-31 19:01:01 -05:00
#ifdef SDCARDDETECT
#error SDCARDDETECT is now SD_DETECT_PIN. Please update your pins definitions.
#endif
#ifdef SDCARDDETECTINVERTED
#error SDCARDDETECTINVERTED is now SD_DETECT_INVERTED. Please update your configuration.
#endif
#ifdef BTENABLED
#error BTENABLED has been replaced with BLUETOOTH. Please update your configuration.
#endif
2015-08-01 10:04:57 -05:00
#ifdef CUSTOM_MENDEL_NAME
#error CUSTOM_MENDEL_NAME deprecated - use CUSTOM_MACHINE_NAME instead
#endif
#ifdef HAS_AUTOMATIC_VERSIONING
#error HAS_AUTOMATIC_VERSIONING deprecated - use USE_AUTOMATIC_VERSIONING instead
#endif
#endif //SANITYCHECK_H