Marlin_Firmware/Marlin/src/gcode/bedlevel/abl/G29.cpp

1010 lines
32 KiB
C++
Raw Normal View History

/**
* Marlin 3D Printer Firmware
2019-06-27 23:57:50 -05:00
* Copyright (c) 2019 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
2019-06-27 23:57:50 -05:00
* Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <http://www.gnu.org/licenses/>.
*
*/
2017-09-08 15:35:25 -05:00
/**
* G29.cpp - Auto Bed Leveling
*/
#include "../../../inc/MarlinConfig.h"
2019-02-24 20:29:03 -06:00
#if HAS_ABL_NOT_UBL
2017-09-08 15:35:25 -05:00
#include "../../gcode.h"
#include "../../../feature/bedlevel/bedlevel.h"
#include "../../../module/motion.h"
#include "../../../module/planner.h"
#include "../../../module/stepper.h"
#include "../../../module/probe.h"
#include "../../queue.h"
2017-09-08 15:35:25 -05:00
#if HAS_DISPLAY
2017-09-08 15:35:25 -05:00
#include "../../../lcd/ultralcd.h"
#endif
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
#include "../../../libs/least_squares_fit.h"
#endif
2018-05-01 07:05:18 -05:00
#if ABL_PLANAR
#include "../../../libs/vector_3.h"
#endif
#define DEBUG_OUT ENABLED(DEBUG_LEVELING_FEATURE)
#include "../../../core/debug_out.h"
2019-04-26 02:32:01 -05:00
#if ENABLED(EXTENSIBLE_UI)
#include "../../../lcd/extensible_ui/ui_api.h"
#endif
#if HOTENDS > 1
#include "../../../module/tool_change.h"
#endif
#if ABL_GRID
#if ENABLED(PROBE_Y_FIRST)
#define PR_OUTER_VAR xCount
#define PR_OUTER_END abl_grid_points_x
#define PR_INNER_VAR yCount
#define PR_INNER_END abl_grid_points_y
#else
#define PR_OUTER_VAR yCount
#define PR_OUTER_END abl_grid_points_y
#define PR_INNER_VAR xCount
#define PR_INNER_END abl_grid_points_x
#endif
#endif
#if ENABLED(G29_RETRY_AND_RECOVER)
#define G29_RETURN(b) return b;
#else
#define G29_RETURN(b) return;
2018-07-25 18:49:32 -05:00
#endif
/**
* G29: Detailed Z probe, probes the bed at 3 or more points.
* Will fail if the printer has not been homed with G28.
*
* Enhanced G29 Auto Bed Leveling Probe Routine
*
* O Auto-level only if needed
*
* D Dry-Run mode. Just evaluate the bed Topology - Don't apply
* or alter the bed level data. Useful to check the topology
* after a first run of G29.
*
* J Jettison current bed leveling data
*
* V Set the verbose level (0-4). Example: "G29 V3"
*
* Parameters With LINEAR leveling only:
*
* P Set the size of the grid that will be probed (P x P points).
* Example: "G29 P4"
*
* X Set the X size of the grid that will be probed (X x Y points).
* Example: "G29 X7 Y5"
*
* Y Set the Y size of the grid that will be probed (X x Y points).
*
* T Generate a Bed Topology Report. Example: "G29 P5 T" for a detailed report.
* This is useful for manual bed leveling and finding flaws in the bed (to
* assist with part placement).
* Not supported by non-linear delta printer bed leveling.
*
* Parameters With LINEAR and BILINEAR leveling only:
*
* S Set the XY travel speed between probe points (in units/min)
*
* H Set bounds to a centered square H x H units in size
*
* -or-
*
* F Set the Front limit of the probing grid
* B Set the Back limit of the probing grid
* L Set the Left limit of the probing grid
* R Set the Right limit of the probing grid
*
* Parameters with DEBUG_LEVELING_FEATURE only:
*
* C Make a totally fake grid with no actual probing.
* For use in testing when no probing is possible.
*
* Parameters with BILINEAR leveling only:
*
* Z Supply an additional Z probe offset
*
* Extra parameters with PROBE_MANUALLY:
*
* To do manual probing simply repeat G29 until the procedure is complete.
* The first G29 accepts parameters. 'G29 Q' for status, 'G29 A' to abort.
*
* Q Query leveling and G29 state
*
* A Abort current leveling procedure
*
* Extra parameters with BILINEAR only:
*
* W Write a mesh point. (If G29 is idle.)
* I X index for mesh point
* J Y index for mesh point
* X X for mesh point, overrides I
* Y Y for mesh point, overrides J
* Z Z for mesh point. Otherwise, raw current Z.
*
* Without PROBE_MANUALLY:
*
* E By default G29 will engage the Z probe, test the bed, then disengage.
* Include "E" to engage/disengage the Z probe for each sample.
* There's no extra effect if you have a fixed Z probe.
*
*/
G29_TYPE GcodeSuite::G29() {
#if EITHER(DEBUG_LEVELING_FEATURE, PROBE_MANUALLY)
2018-01-23 13:08:46 -06:00
const bool seenQ = parser.seen('Q');
#else
constexpr bool seenQ = false;
#endif
// G29 Q is also available if debugging
#if ENABLED(DEBUG_LEVELING_FEATURE)
const uint8_t old_debug_flags = marlin_debug_flags;
if (seenQ) marlin_debug_flags |= MARLIN_DEBUG_LEVELING;
if (DEBUGGING(LEVELING)) {
2017-10-14 02:46:05 -05:00
DEBUG_POS(">>> G29", current_position);
log_machine_info();
}
marlin_debug_flags = old_debug_flags;
#if DISABLED(PROBE_MANUALLY)
if (seenQ) G29_RETURN(false);
#endif
#endif
#if ENABLED(PROBE_MANUALLY)
2018-01-23 13:08:46 -06:00
const bool seenA = parser.seen('A');
#else
2018-01-23 13:08:46 -06:00
constexpr bool seenA = false;
#endif
2018-01-23 13:08:46 -06:00
const bool no_action = seenA || seenQ,
faux =
#if ENABLED(DEBUG_LEVELING_FEATURE) && DISABLED(PROBE_MANUALLY)
parser.boolval('C')
#else
no_action
#endif
;
// Don't allow auto-leveling without homing first
if (axis_unhomed_error()) G29_RETURN(false);
if (!no_action && planner.leveling_active && parser.boolval('O')) { // Auto-level only if needed
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPGM("> Auto-level not needed, skip\n<<< G29");
G29_RETURN(false);
}
2018-06-11 21:57:26 -05:00
// Define local vars 'static' for manual probing, 'auto' otherwise
#if ENABLED(PROBE_MANUALLY)
#define ABL_VAR static
#else
#define ABL_VAR
#endif
ABL_VAR int verbose_level;
ABL_VAR float xProbe, yProbe, measured_z;
ABL_VAR bool dryrun, abl_should_enable;
#if EITHER(PROBE_MANUALLY, AUTO_BED_LEVELING_LINEAR)
ABL_VAR int abl_probe_index;
#endif
#if HAS_SOFTWARE_ENDSTOPS && ENABLED(PROBE_MANUALLY)
ABL_VAR bool saved_soft_endstops_state = true;
#endif
#if ABL_GRID
#if ENABLED(PROBE_MANUALLY)
ABL_VAR uint8_t PR_OUTER_VAR;
ABL_VAR int8_t PR_INNER_VAR;
#endif
ABL_VAR int left_probe_bed_position, right_probe_bed_position, front_probe_bed_position, back_probe_bed_position;
ABL_VAR float xGridSpacing = 0, yGridSpacing = 0;
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
ABL_VAR uint8_t abl_grid_points_x = GRID_MAX_POINTS_X,
abl_grid_points_y = GRID_MAX_POINTS_Y;
ABL_VAR bool do_topography_map;
#else // Bilinear
uint8_t constexpr abl_grid_points_x = GRID_MAX_POINTS_X,
abl_grid_points_y = GRID_MAX_POINTS_Y;
#endif
2017-09-08 15:35:25 -05:00
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
ABL_VAR int abl_points;
2017-09-08 15:35:25 -05:00
#elif ENABLED(PROBE_MANUALLY) // Bilinear
int constexpr abl_points = GRID_MAX_POINTS;
#endif
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
ABL_VAR float zoffset;
#elif ENABLED(AUTO_BED_LEVELING_LINEAR)
ABL_VAR int indexIntoAB[GRID_MAX_POINTS_X][GRID_MAX_POINTS_Y];
ABL_VAR float eqnAMatrix[(GRID_MAX_POINTS) * 3], // "A" matrix of the linear system of equations
eqnBVector[GRID_MAX_POINTS], // "B" vector of Z points
mean;
#endif
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
2017-09-08 15:35:25 -05:00
#if ENABLED(PROBE_MANUALLY)
int constexpr abl_points = 3; // used to show total points
2017-09-08 15:35:25 -05:00
#endif
// Probe at 3 arbitrary points
ABL_VAR vector_3 points[3] = {
vector_3(PROBE_PT_1_X, PROBE_PT_1_Y, 0),
vector_3(PROBE_PT_2_X, PROBE_PT_2_Y, 0),
vector_3(PROBE_PT_3_X, PROBE_PT_3_Y, 0)
};
#endif // AUTO_BED_LEVELING_3POINT
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
struct linear_fit_data lsf_results;
incremental_LSF_reset(&lsf_results);
#endif
/**
* On the initial G29 fetch command parameters.
*/
if (!g29_in_progress) {
#if HOTENDS > 1
if (active_extruder != 0) tool_change(0);
#endif
#if EITHER(PROBE_MANUALLY, AUTO_BED_LEVELING_LINEAR)
abl_probe_index = -1;
#endif
abl_should_enable = planner.leveling_active;
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
2018-02-01 03:17:42 -06:00
const bool seen_w = parser.seen('W');
if (seen_w) {
if (!leveling_is_valid()) {
SERIAL_ERROR_MSG("No bilinear grid");
G29_RETURN(false);
}
2017-11-02 23:59:42 -05:00
const float rz = parser.seenval('Z') ? RAW_Z_POSITION(parser.value_linear_units()) : current_position[Z_AXIS];
if (!WITHIN(rz, -10, 10)) {
SERIAL_ERROR_MSG("Bad Z value");
G29_RETURN(false);
}
2017-11-02 23:59:42 -05:00
const float rx = RAW_X_POSITION(parser.linearval('X', NAN)),
ry = RAW_Y_POSITION(parser.linearval('Y', NAN));
int8_t i = parser.byteval('I', -1), j = parser.byteval('J', -1);
2017-11-02 23:59:42 -05:00
if (!isnan(rx) && !isnan(ry)) {
// Get nearest i / j from rx / ry
i = (rx - bilinear_start[X_AXIS] + 0.5 * xGridSpacing) / xGridSpacing;
j = (ry - bilinear_start[Y_AXIS] + 0.5 * yGridSpacing) / yGridSpacing;
2019-07-10 03:33:28 -05:00
LIMIT(i, 0, GRID_MAX_POINTS_X - 1);
LIMIT(j, 0, GRID_MAX_POINTS_Y - 1);
}
if (WITHIN(i, 0, GRID_MAX_POINTS_X - 1) && WITHIN(j, 0, GRID_MAX_POINTS_Y)) {
set_bed_leveling_enabled(false);
2017-11-02 23:59:42 -05:00
z_values[i][j] = rz;
#if ENABLED(ABL_BILINEAR_SUBDIVISION)
bed_level_virt_interpolate();
#endif
#if ENABLED(EXTENSIBLE_UI)
ExtUI::onMeshUpdate(i, j, rz);
#endif
set_bed_leveling_enabled(abl_should_enable);
2017-12-10 21:17:07 -06:00
if (abl_should_enable) report_current_position();
}
G29_RETURN(false);
} // parser.seen('W')
2018-02-01 03:17:42 -06:00
#else
constexpr bool seen_w = false;
#endif
2017-12-25 08:29:31 -06:00
// Jettison bed leveling data
2018-02-01 03:17:42 -06:00
if (!seen_w && parser.seen('J')) {
2017-12-25 08:29:31 -06:00
reset_bed_level();
G29_RETURN(false);
2017-12-25 08:29:31 -06:00
}
verbose_level = parser.intval('V');
if (!WITHIN(verbose_level, 0, 4)) {
SERIAL_ECHOLNPGM("?(V)erbose level is implausible (0-4).");
G29_RETURN(false);
}
dryrun = parser.boolval('D')
#if ENABLED(PROBE_MANUALLY)
|| no_action
#endif
;
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
do_topography_map = verbose_level > 2 || parser.boolval('T');
// X and Y specify points in each direction, overriding the default
// These values may be saved with the completed mesh
abl_grid_points_x = parser.intval('X', GRID_MAX_POINTS_X);
abl_grid_points_y = parser.intval('Y', GRID_MAX_POINTS_Y);
if (parser.seenval('P')) abl_grid_points_x = abl_grid_points_y = parser.value_int();
2018-02-10 16:53:58 -06:00
if (!WITHIN(abl_grid_points_x, 2, GRID_MAX_POINTS_X)) {
SERIAL_ECHOLNPGM("?Probe points (X) is implausible (2-" STRINGIFY(GRID_MAX_POINTS_X) ").");
G29_RETURN(false);
2018-02-10 16:53:58 -06:00
}
if (!WITHIN(abl_grid_points_y, 2, GRID_MAX_POINTS_Y)) {
SERIAL_ECHOLNPGM("?Probe points (Y) is implausible (2-" STRINGIFY(GRID_MAX_POINTS_Y) ").");
G29_RETURN(false);
}
abl_points = abl_grid_points_x * abl_grid_points_y;
mean = 0;
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
zoffset = parser.linearval('Z');
#endif
#if ABL_GRID
xy_probe_feedrate_mm_s = MMM_TO_MMS(parser.linearval('S', XY_PROBE_SPEED));
if (parser.seen('H')) {
const int16_t size = (int16_t)parser.value_linear_units();
left_probe_bed_position = _MAX(X_CENTER - size / 2, MIN_PROBE_X);
right_probe_bed_position = _MIN(left_probe_bed_position + size, MAX_PROBE_X);
front_probe_bed_position = _MAX(Y_CENTER - size / 2, MIN_PROBE_Y);
back_probe_bed_position = _MIN(front_probe_bed_position + size, MAX_PROBE_Y);
}
else {
left_probe_bed_position = parser.seenval('L') ? (int)RAW_X_POSITION(parser.value_linear_units()) : LEFT_PROBE_BED_POSITION;
right_probe_bed_position = parser.seenval('R') ? (int)RAW_X_POSITION(parser.value_linear_units()) : RIGHT_PROBE_BED_POSITION;
front_probe_bed_position = parser.seenval('F') ? (int)RAW_Y_POSITION(parser.value_linear_units()) : FRONT_PROBE_BED_POSITION;
back_probe_bed_position = parser.seenval('B') ? (int)RAW_Y_POSITION(parser.value_linear_units()) : BACK_PROBE_BED_POSITION;
}
if (
#if IS_SCARA || ENABLED(DELTA)
!position_is_reachable_by_probe(left_probe_bed_position, 0)
|| !position_is_reachable_by_probe(right_probe_bed_position, 0)
|| !position_is_reachable_by_probe(0, front_probe_bed_position)
|| !position_is_reachable_by_probe(0, back_probe_bed_position)
#else
!position_is_reachable_by_probe(left_probe_bed_position, front_probe_bed_position)
|| !position_is_reachable_by_probe(right_probe_bed_position, back_probe_bed_position)
#endif
) {
SERIAL_ECHOLNPGM("? (L,R,F,B) out of bounds.");
G29_RETURN(false);
}
// probe at the points of a lattice grid
xGridSpacing = (right_probe_bed_position - left_probe_bed_position) / (abl_grid_points_x - 1);
yGridSpacing = (back_probe_bed_position - front_probe_bed_position) / (abl_grid_points_y - 1);
#endif // ABL_GRID
if (verbose_level > 0) {
SERIAL_ECHOPGM("G29 Auto Bed Leveling");
if (dryrun) SERIAL_ECHOPGM(" (DRYRUN)");
2017-12-25 08:29:31 -06:00
SERIAL_EOL();
}
planner.synchronize();
2017-12-25 08:29:31 -06:00
// Disable auto bed leveling during G29.
2017-12-25 06:32:33 -06:00
// Be formal so G29 can be done successively without G28.
2018-01-23 13:08:46 -06:00
if (!no_action) set_bed_leveling_enabled(false);
#if HAS_BED_PROBE
// Deploy the probe. Probe will raise if needed.
if (DEPLOY_PROBE()) {
2017-12-25 06:32:33 -06:00
set_bed_leveling_enabled(abl_should_enable);
G29_RETURN(false);
}
#endif
if (!faux) setup_for_endstop_or_probe_move();
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
#if ENABLED(PROBE_MANUALLY)
if (!no_action)
#endif
if ( xGridSpacing != bilinear_grid_spacing[X_AXIS]
|| yGridSpacing != bilinear_grid_spacing[Y_AXIS]
2017-11-02 23:59:42 -05:00
|| left_probe_bed_position != bilinear_start[X_AXIS]
|| front_probe_bed_position != bilinear_start[Y_AXIS]
) {
// Reset grid to 0.0 or "not probed". (Also disables ABL)
reset_bed_level();
// Initialize a grid with the given dimensions
bilinear_grid_spacing[X_AXIS] = xGridSpacing;
bilinear_grid_spacing[Y_AXIS] = yGridSpacing;
2017-11-02 23:59:42 -05:00
bilinear_start[X_AXIS] = left_probe_bed_position;
bilinear_start[Y_AXIS] = front_probe_bed_position;
// Can't re-enable (on error) until the new grid is written
abl_should_enable = false;
}
#endif // AUTO_BED_LEVELING_BILINEAR
#if ENABLED(AUTO_BED_LEVELING_3POINT)
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPGM("> 3-point Leveling");
// Probe at 3 arbitrary points
points[0].z = points[1].z = points[2].z = 0;
#endif // AUTO_BED_LEVELING_3POINT
} // !g29_in_progress
#if ENABLED(PROBE_MANUALLY)
// For manual probing, get the next index to probe now.
// On the first probe this will be incremented to 0.
if (!no_action) {
++abl_probe_index;
g29_in_progress = true;
}
// Abort current G29 procedure, go back to idle state
if (seenA && g29_in_progress) {
SERIAL_ECHOLNPGM("Manual G29 aborted");
#if HAS_SOFTWARE_ENDSTOPS
soft_endstops_enabled = saved_soft_endstops_state;
#endif
2017-12-25 06:32:33 -06:00
set_bed_leveling_enabled(abl_should_enable);
g29_in_progress = false;
#if ENABLED(LCD_BED_LEVELING)
ui.wait_for_bl_move = false;
#endif
}
// Query G29 status
if (verbose_level || seenQ) {
SERIAL_ECHOPGM("Manual G29 ");
if (g29_in_progress) {
SERIAL_ECHOPAIR("point ", _MIN(abl_probe_index + 1, abl_points));
SERIAL_ECHOLNPAIR(" of ", abl_points);
}
else
SERIAL_ECHOLNPGM("idle");
}
if (no_action) G29_RETURN(false);
if (abl_probe_index == 0) {
// For the initial G29 S2 save software endstop state
#if HAS_SOFTWARE_ENDSTOPS
saved_soft_endstops_state = soft_endstops_enabled;
#endif
// Move close to the bed before the first point
do_blocking_move_to_z(0);
}
else {
#if EITHER(AUTO_BED_LEVELING_LINEAR, AUTO_BED_LEVELING_3POINT)
const uint16_t index = abl_probe_index - 1;
#endif
// For G29 after adjusting Z.
// Save the previous Z before going to the next point
measured_z = current_position[Z_AXIS];
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
mean += measured_z;
eqnBVector[index] = measured_z;
eqnAMatrix[index + 0 * abl_points] = xProbe;
eqnAMatrix[index + 1 * abl_points] = yProbe;
eqnAMatrix[index + 2 * abl_points] = 1;
incremental_LSF(&lsf_results, xProbe, yProbe, measured_z);
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
points[index].z = measured_z;
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
z_values[xCount][yCount] = measured_z + zoffset;
#if ENABLED(EXTENSIBLE_UI)
ExtUI::onMeshUpdate(xCount, yCount, z_values[xCount][yCount]);
#endif
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR("Save X", xCount, " Y", yCount, " Z", measured_z + zoffset);
#endif
}
//
// If there's another point to sample, move there with optional lift.
//
#if ABL_GRID
// Skip any unreachable points
while (abl_probe_index < abl_points) {
// Set xCount, yCount based on abl_probe_index, with zig-zag
PR_OUTER_VAR = abl_probe_index / PR_INNER_END;
PR_INNER_VAR = abl_probe_index - (PR_OUTER_VAR * PR_INNER_END);
// Probe in reverse order for every other row/column
bool zig = (PR_OUTER_VAR & 1); // != ((PR_OUTER_END) & 1);
if (zig) PR_INNER_VAR = (PR_INNER_END - 1) - PR_INNER_VAR;
const float xBase = xCount * xGridSpacing + left_probe_bed_position,
yBase = yCount * yGridSpacing + front_probe_bed_position;
xProbe = FLOOR(xBase + (xBase < 0 ? 0 : 0.5));
yProbe = FLOOR(yBase + (yBase < 0 ? 0 : 0.5));
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
indexIntoAB[xCount][yCount] = abl_probe_index;
#endif
// Keep looping till a reachable point is found
2017-11-02 23:59:42 -05:00
if (position_is_reachable(xProbe, yProbe)) break;
++abl_probe_index;
}
// Is there a next point to move to?
if (abl_probe_index < abl_points) {
_manual_goto_xy(xProbe, yProbe); // Can be used here too!
#if HAS_SOFTWARE_ENDSTOPS
// Disable software endstops to allow manual adjustment
// If G29 is not completed, they will not be re-enabled
soft_endstops_enabled = false;
#endif
G29_RETURN(false);
}
else {
// Leveling done! Fall through to G29 finishing code below
SERIAL_ECHOLNPGM("Grid probing done.");
// Re-enable software endstops, if needed
#if HAS_SOFTWARE_ENDSTOPS
soft_endstops_enabled = saved_soft_endstops_state;
#endif
}
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// Probe at 3 arbitrary points
if (abl_probe_index < abl_points) {
2017-11-02 23:59:42 -05:00
xProbe = points[abl_probe_index].x;
yProbe = points[abl_probe_index].y;
2017-12-25 08:29:31 -06:00
_manual_goto_xy(xProbe, yProbe);
#if HAS_SOFTWARE_ENDSTOPS
// Disable software endstops to allow manual adjustment
// If G29 is not completed, they will not be re-enabled
soft_endstops_enabled = false;
#endif
G29_RETURN(false);
}
else {
SERIAL_ECHOLNPGM("3-point probing done.");
// Re-enable software endstops, if needed
#if HAS_SOFTWARE_ENDSTOPS
soft_endstops_enabled = saved_soft_endstops_state;
#endif
if (!dryrun) {
vector_3 planeNormal = vector_3::cross(points[0] - points[1], points[2] - points[1]).get_normal();
if (planeNormal.z < 0) {
planeNormal.x *= -1;
planeNormal.y *= -1;
planeNormal.z *= -1;
}
planner.bed_level_matrix = matrix_3x3::create_look_at(planeNormal);
// Can't re-enable (on error) until the new grid is written
abl_should_enable = false;
}
}
#endif // AUTO_BED_LEVELING_3POINT
#else // !PROBE_MANUALLY
{
const ProbePtRaise raise_after = parser.boolval('E') ? PROBE_PT_STOW : PROBE_PT_RAISE;
measured_z = 0;
#if ABL_GRID
bool zig = PR_OUTER_END & 1; // Always end at RIGHT and BACK_PROBE_BED_POSITION
2017-11-06 22:57:05 -06:00
measured_z = 0;
// Outer loop is Y with PROBE_Y_FIRST disabled
for (uint8_t PR_OUTER_VAR = 0; PR_OUTER_VAR < PR_OUTER_END && !isnan(measured_z); PR_OUTER_VAR++) {
int8_t inStart, inStop, inInc;
if (zig) { // away from origin
inStart = 0;
inStop = PR_INNER_END;
inInc = 1;
}
else { // towards origin
inStart = PR_INNER_END - 1;
inStop = -1;
inInc = -1;
}
zig ^= true; // zag
// An index to print current state
uint8_t pt_index = (PR_OUTER_VAR) * (PR_INNER_END) + 1;
// Inner loop is Y with PROBE_Y_FIRST enabled
for (int8_t PR_INNER_VAR = inStart; PR_INNER_VAR != inStop; pt_index++, PR_INNER_VAR += inInc) {
const float xBase = left_probe_bed_position + xGridSpacing * xCount,
yBase = front_probe_bed_position + yGridSpacing * yCount;
xProbe = FLOOR(xBase + (xBase < 0 ? 0 : 0.5));
yProbe = FLOOR(yBase + (yBase < 0 ? 0 : 0.5));
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
indexIntoAB[xCount][yCount] = ++abl_probe_index; // 0...
#endif
#if IS_KINEMATIC
// Avoid probing outside the round or hexagonal area
2017-11-02 23:59:42 -05:00
if (!position_is_reachable_by_probe(xProbe, yProbe)) continue;
#endif
if (verbose_level) SERIAL_ECHOLNPAIR("Probing mesh point ", int(pt_index), "/", int(GRID_MAX_POINTS), ".");
#if HAS_DISPLAY
ui.status_printf_P(0, PSTR(MSG_PROBING_MESH " %i/%i"), int(pt_index), int(GRID_MAX_POINTS));
#endif
measured_z = faux ? 0.001 * random(-100, 101) : probe_pt(xProbe, yProbe, raise_after, verbose_level);
if (isnan(measured_z)) {
2017-12-25 06:32:33 -06:00
set_bed_leveling_enabled(abl_should_enable);
break; // Breaks out of both loops
}
#if ENABLED(AUTO_BED_LEVELING_LINEAR)
mean += measured_z;
eqnBVector[abl_probe_index] = measured_z;
eqnAMatrix[abl_probe_index + 0 * abl_points] = xProbe;
eqnAMatrix[abl_probe_index + 1 * abl_points] = yProbe;
eqnAMatrix[abl_probe_index + 2 * abl_points] = 1;
incremental_LSF(&lsf_results, xProbe, yProbe, measured_z);
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
z_values[xCount][yCount] = measured_z + zoffset;
#if ENABLED(EXTENSIBLE_UI)
ExtUI::onMeshUpdate(xCount, yCount, z_values[xCount][yCount]);
#endif
#endif
abl_should_enable = false;
idle();
} // inner
} // outer
#elif ENABLED(AUTO_BED_LEVELING_3POINT)
// Probe at 3 arbitrary points
for (uint8_t i = 0; i < 3; ++i) {
if (verbose_level) SERIAL_ECHOLNPAIR("Probing point ", int(i), "/3.");
#if HAS_DISPLAY
ui.status_printf_P(0, PSTR(MSG_PROBING_MESH " %i/3"), int(i));
#endif
// Retain the last probe position
2017-11-02 23:59:42 -05:00
xProbe = points[i].x;
yProbe = points[i].y;
measured_z = faux ? 0.001 * random(-100, 101) : probe_pt(xProbe, yProbe, raise_after, verbose_level);
if (isnan(measured_z)) {
2017-12-25 06:32:33 -06:00
set_bed_leveling_enabled(abl_should_enable);
break;
}
points[i].z = measured_z;
}
if (!dryrun && !isnan(measured_z)) {
vector_3 planeNormal = vector_3::cross(points[0] - points[1], points[2] - points[1]).get_normal();
if (planeNormal.z < 0) {
planeNormal.x *= -1;
planeNormal.y *= -1;
planeNormal.z *= -1;
}
planner.bed_level_matrix = matrix_3x3::create_look_at(planeNormal);
// Can't re-enable (on error) until the new grid is written
abl_should_enable = false;
}
#endif // AUTO_BED_LEVELING_3POINT
#if HAS_DISPLAY
ui.reset_status();
#endif
// Stow the probe. No raise for FIX_MOUNTED_PROBE.
if (STOW_PROBE()) {
2017-12-25 06:32:33 -06:00
set_bed_leveling_enabled(abl_should_enable);
measured_z = NAN;
}
}
#endif // !PROBE_MANUALLY
//
// G29 Finishing Code
//
// Unless this is a dry run, auto bed leveling will
// definitely be enabled after this point.
//
// If code above wants to continue leveling, it should
// return or loop before this point.
//
if (DEBUGGING(LEVELING)) DEBUG_POS("> probing complete", current_position);
#if ENABLED(PROBE_MANUALLY)
g29_in_progress = false;
#if ENABLED(LCD_BED_LEVELING)
ui.wait_for_bl_move = false;
#endif
#endif
// Calculate leveling, print reports, correct the position
if (!isnan(measured_z)) {
#if ENABLED(AUTO_BED_LEVELING_BILINEAR)
if (!dryrun) extrapolate_unprobed_bed_level();
print_bilinear_leveling_grid();
refresh_bed_level();
#if ENABLED(ABL_BILINEAR_SUBDIVISION)
print_bilinear_leveling_grid_virt();
#endif
#elif ENABLED(AUTO_BED_LEVELING_LINEAR)
// For LINEAR leveling calculate matrix, print reports, correct the position
/**
* solve the plane equation ax + by + d = z
* A is the matrix with rows [x y 1] for all the probed points
* B is the vector of the Z positions
* the normal vector to the plane is formed by the coefficients of the
* plane equation in the standard form, which is Vx*x+Vy*y+Vz*z+d = 0
* so Vx = -a Vy = -b Vz = 1 (we want the vector facing towards positive Z
*/
float plane_equation_coefficients[3];
finish_incremental_LSF(&lsf_results);
plane_equation_coefficients[0] = -lsf_results.A; // We should be able to eliminate the '-' on these three lines and down below
plane_equation_coefficients[1] = -lsf_results.B; // but that is not yet tested.
plane_equation_coefficients[2] = -lsf_results.D;
mean /= abl_points;
if (verbose_level) {
SERIAL_ECHOPAIR_F("Eqn coefficients: a: ", plane_equation_coefficients[0], 8);
SERIAL_ECHOPAIR_F(" b: ", plane_equation_coefficients[1], 8);
SERIAL_ECHOPAIR_F(" d: ", plane_equation_coefficients[2], 8);
if (verbose_level > 2)
SERIAL_ECHOPAIR_F("\nMean of sampled points: ", mean, 8);
SERIAL_EOL();
}
// Create the matrix but don't correct the position yet
if (!dryrun)
planner.bed_level_matrix = matrix_3x3::create_look_at(
vector_3(-plane_equation_coefficients[0], -plane_equation_coefficients[1], 1) // We can eliminate the '-' here and up above
);
// Show the Topography map if enabled
if (do_topography_map) {
SERIAL_ECHOLNPGM("\nBed Height Topography:\n"
" +--- BACK --+\n"
" | |\n"
" L | (+) | R\n"
" E | | I\n"
" F | (-) N (+) | G\n"
" T | | H\n"
" | (-) | T\n"
" | |\n"
" O-- FRONT --+\n"
" (0,0)");
float min_diff = 999;
for (int8_t yy = abl_grid_points_y - 1; yy >= 0; yy--) {
for (uint8_t xx = 0; xx < abl_grid_points_x; xx++) {
int ind = indexIntoAB[xx][yy];
float diff = eqnBVector[ind] - mean,
x_tmp = eqnAMatrix[ind + 0 * abl_points],
y_tmp = eqnAMatrix[ind + 1 * abl_points],
z_tmp = 0;
apply_rotation_xyz(planner.bed_level_matrix, x_tmp, y_tmp, z_tmp);
NOMORE(min_diff, eqnBVector[ind] - z_tmp);
if (diff >= 0.0)
SERIAL_ECHOPGM(" +"); // Include + for column alignment
else
SERIAL_CHAR(' ');
SERIAL_ECHO_F(diff, 5);
} // xx
SERIAL_EOL();
} // yy
SERIAL_EOL();
if (verbose_level > 3) {
SERIAL_ECHOLNPGM("\nCorrected Bed Height vs. Bed Topology:");
for (int8_t yy = abl_grid_points_y - 1; yy >= 0; yy--) {
for (uint8_t xx = 0; xx < abl_grid_points_x; xx++) {
int ind = indexIntoAB[xx][yy];
float x_tmp = eqnAMatrix[ind + 0 * abl_points],
y_tmp = eqnAMatrix[ind + 1 * abl_points],
z_tmp = 0;
apply_rotation_xyz(planner.bed_level_matrix, x_tmp, y_tmp, z_tmp);
float diff = eqnBVector[ind] - z_tmp - min_diff;
if (diff >= 0.0)
SERIAL_ECHOPGM(" +");
// Include + for column alignment
else
SERIAL_CHAR(' ');
SERIAL_ECHO_F(diff, 5);
} // xx
SERIAL_EOL();
} // yy
SERIAL_EOL();
}
} //do_topography_map
#endif // AUTO_BED_LEVELING_LINEAR
#if ABL_PLANAR
// For LINEAR and 3POINT leveling correct the current position
if (verbose_level > 0)
planner.bed_level_matrix.debug(PSTR("\n\nBed Level Correction Matrix:"));
if (!dryrun) {
//
// Correct the current XYZ position based on the tilted plane.
//
if (DEBUGGING(LEVELING)) DEBUG_POS("G29 uncorrected XYZ", current_position);
float converted[XYZ];
COPY(converted, current_position);
planner.leveling_active = true;
planner.unapply_leveling(converted); // use conversion machinery
planner.leveling_active = false;
// Use the last measured distance to the bed, if possible
if ( NEAR(current_position[X_AXIS], xProbe - (X_PROBE_OFFSET_FROM_EXTRUDER))
&& NEAR(current_position[Y_AXIS], yProbe - (Y_PROBE_OFFSET_FROM_EXTRUDER))
) {
const float simple_z = current_position[Z_AXIS] - measured_z;
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR("Probed Z", simple_z, " Matrix Z", converted[Z_AXIS], " Discrepancy ", simple_z - converted[Z_AXIS]);
converted[Z_AXIS] = simple_z;
}
// The rotated XY and corrected Z are now current_position
COPY(current_position, converted);
if (DEBUGGING(LEVELING)) DEBUG_POS("G29 corrected XYZ", current_position);
}
#elif ENABLED(AUTO_BED_LEVELING_BILINEAR)
if (!dryrun) {
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR("G29 uncorrected Z:", current_position[Z_AXIS]);
// Unapply the offset because it is going to be immediately applied
// and cause compensation movement in Z
current_position[Z_AXIS] -= bilinear_z_offset(current_position);
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR(" corrected Z:", current_position[Z_AXIS]);
}
#endif // ABL_PLANAR
// Auto Bed Leveling is complete! Enable if possible.
planner.leveling_active = dryrun ? abl_should_enable : true;
} // !isnan(measured_z)
// Restore state after probing
if (!faux) clean_up_after_endstop_or_probe_move();
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPGM("<<< G29");
if (planner.leveling_active)
sync_plan_position();
2018-04-30 03:25:47 -05:00
#if HAS_BED_PROBE && defined(Z_AFTER_PROBING)
move_z_after_probing();
#endif
2019-07-14 04:28:38 -05:00
#ifdef Z_PROBE_END_SCRIPT
if (DEBUGGING(LEVELING)) DEBUG_ECHOLNPAIR("Z Probe End Script: ", Z_PROBE_END_SCRIPT);
planner.synchronize();
process_subcommands_now_P(PSTR(Z_PROBE_END_SCRIPT));
#endif
report_current_position();
2018-07-25 18:49:32 -05:00
G29_RETURN(isnan(measured_z));
}
2017-09-08 15:35:25 -05:00
2019-02-24 20:29:03 -06:00
#endif // HAS_ABL_NOT_UBL